Burkert Type 8611 User Manual

Page 74

Advertising
background image

74

FunctionsoftheConfigurationLevel

Setting the controller parameters in the menu:

BACK

01.50

01.50

01.00

00.50

00.10

00.50

01.00

01.00

01.00

NO

NO

KP1

KP2

TREG

TN

DEAD

KP_T

TN_T

DE_T

STRT

INV

ZERO

01.50

KP1

*

)

01.50

KP2

*

)

01.00

TREG

00.50

TN

00.10

DEAD

00.50

KP_T

*

)

01.00

TN_T

01.00

DE_T

04.00

STRT

accept value

AOUT

PARA

KP1, proportional coefficient 1
*

)

Changing the decimal place

(see Table 28)
KP2, proportional coefficient 2

Cycle time for controller [s]
(display only for

MODE = PVC,

3P – T

,

2P – T

,)

Reset time [s]
(display only for

MODE = SCV,

0 – 10, 4 – 20

,

2P – T

,

3P – T

,)

Dead zone absolute. Unit and display of
decimal place analogous to

UNIT.

Proportional coefficient for cascaded
temperature control
(display only for

MODE = T + F)

Reset time in [s] for cascaded
temperature control
(display only for

MODE = T + F)

Dead zone absolute for cascaded temper-
ature control (display only for
MODE = T + F). Unit and display of decimal
place analogous to

UNIT.

Definition of start value for manipulated
variable
(display only for

MODE = SCV, 0 – 10,

4 – 20, 2p - T, 3P - T)

Effective direction between process value
and valve position

Zero point shut-off
(if default < 2 % of the set-point value
range). Display only for

INV = NO

set value

NO

INV

YES

INV

NO

ZERO

YES

ZERO

Figure 54:

PARA; Adjusting the controller parameters

english

Type 8611