Electrical data, Electrical data without bus control 24 v dc, Electrical data with as-interface bus control – Burkert Type 8695 User Manual

Page 15: Electrical data with devicenet bus control, 7 electrical data

Advertising
background image

15

Technicaldata

6.7

electrical data

6.7.1

electrical data without bus control 24 V Dc

Connections

Circular plug-in connector (M12 x 1, 8-pole)

Pilot valve
Operating voltage

24 V DC ± 10% - max. residual ripple 10 %

Power input

max. 1 W

Output

max. 100 mA per output

Display

max. 20 mA per illustrated illuminated display (LED)

6.7.2

electrical data with as-interface bus control

Connections

Circular plug-in connector (M12 x 1, 4-pole)

Profile

S-B.A.E. (A/B slave, max. 62 slaves/master)

Operating voltage

29.5 V – 31.6 V DC (according to specification)

Outputs
Max. switching capacity

1 W via AS-Interface

Watchdog function

integrated

Max. power consumption

120 mA

Power consumption input during
normal operation
(after current reduction;
valve + 1 end position reached) 90 mA

6.7.3

electrical data with Devicenet bus control

Connections

Circular plug-in connector (M12 x 1, 5-pole)

Operating voltage

11 V – 25 V

Max. power consumption

< 80 mA

Output Pull-in current current ≤ 50 mA

Holding current

≤ 30 mA

english

Type 8695

Advertising