Change assignment of the end position leds, 6 change assignment of the end position leds – Burkert Type 8695 User Manual

Page 45

Advertising
background image

45

AS-Interfaceinstallation

10.6.6 change assignment of the end position leDs

ye

gn

Bot

To

p

To

p

Bot

gn

ye

Jumper for
assignment of
end position LEDs

End position
LED green

End position
LED yellow

ye

gn

Bot

Top

Top

Bot

ye

gn

ye

gn

Bot

Top

Top

Bot

ye

gn

Jumper setting 1:

In the end position top
(Top), the yellow LED
is lit; in the end position
bottom (Bot), the green
LED is lit.

Jumper setting 2:

In the end position top
(Top), the green LED is lit;
in the end position bottom
(Bot), the yellow LED is lit.

Figure 35:

Assignment of the end position LED - AS-Interface

Danger!

risk of electric shock.

▶ Before working on equipment or device, switch off the power supply and secure to prevent reactivation.

▶ Observe applicable accident prevention and safety regulations for electrical equipment.

Procedure:

noTe!

Breakage of the pneumatic connection pieces due to rotational impact.

▶ When unscrewing and screwing in the transparent cap, do not hold the actuator of the process valve but the

connection housing.

Open the control head: turning the transparent cap anti-clockwise.

Body casing

Connection housing

Actuator

Transparent cap

Figure 36:

Open control head

Using the jumpers, assign the required color to the LEDs (see “Figure 35: Assignment of the end position LED
- AS-Interface”).

noTe!

Damage or malfunction due to penetration of dirt and humidity.

▶ To observe degree of protection IP65 / IP67, screw the transparent cap in all the way.

Close the device (assembly tool: 674078

6)

).

6)

The assembly tool (674078) is available from your Bürkert sales office.

english