Burkert Type 8695 User Manual

Page 25

Advertising
background image

25

Installation

Control function i (CFi)
Process valve closed in rest position
Control head

Pilot air outlet

2

2

2

1

Actuator

Upper pilot air port

Lower pilot air port

Process valve open in rest position
Control head

Pilot air outlet

2

2

2

1

Actuator

Upper pilot air port

Lower pilot air port

Table 2:

Pneumatic connection to actuator CFI

If the ambient air is humid, a hose can be connected between pilot air outlet 2

2

of the control head and

the unconnected pilot air port of the actuator for control function A or control function B. As a result, the
spring chamber of the actuator is supplied with dry air from the vent duct of the control head.

7.4

rotating the actuator module
on process valves of series 2100, 2101, 2000 and
2012

The actuator module (control head and actuator) can be rotated for globe valves and angle-seat valves
belonging to series 2100, 2101, 2000 and 2012 only.

The process valve must be in the open position for alignment of the actuator module.

The position of the ports can be aligned steplessly by rotating the actuator module (control head and actuator)
through 360°.

Series 2100 and 2101:
Only the entire actuator module can be rotated. The control head cannot be rotated contrary to the actuator.

english