Technical data

Typ 8750

Dimensions

2x DN

6x DN

L

∅ 91

∅ E

HG

Fig. 6:

Dimensions

dn pipe connection [mm] l [mm]

hG [mm]

∅ e [mm]

15

330

414

101

25

500

412

101

40

700

501

127

50

800

538

157

65

1000

567

157

80

1200

637

261

100

1400

647

261

Tab. 1: Dimensions

7.5. Type label

Example:

8750 24 V DC

single act Pilot 0,6

Pmax 7 bar

Tamb 0°C - +55°C

S/N 001000

00179026

D-74653

Ingelfingen

W14UN

ce

Identification number

Operating voltage /

control

Maximum pressure

Type

Control function
Pilot valve

Bar code

Serial number,
CE symbol

Max. ambient
temperature

Fig. 7:

Example of type label

7.6. fluidic data

Control medium neutral gases, air

Quality classes as per DIN ISO 8573-1

Dust content Class 5: max. particle size 40 μm,

max. particle density 10 mg/m

3

Water content Class 3: max. pressure dew point -20 °C or

min. 10 °C below the lowest operating
temperature

Oil content

Class 5: max. 25 mg/m

3

english