Profibus dp start-up, Settings in bus.comm – Burkert Type 8750 User Manual

Page 35

Advertising
background image

35

PROFIBUS DP start-up

Typ 8750

POS

CMD

PV

SP

P1
P2

MTMP

OUT type

4 - 20 mA

0 - 20 mA

0 - 10 V

0 - 5 V

OUT ANALOG

ENTER

EXIT

ENTER

Output of set-point position

Output of nominal position

Output of the process actual value

Output of the process set-point value

Output of the pressure P1 (input)

Output of the pressure P2 (output)

Output of medium temperature

SELEC

SELEC

Selection
of the
standard
signal

EXIT

Fig. 21: Operating structure OUT ANALOG - analog output

13. profibus dp sTarT-up

procedure:
• Perform the automatic adjustment (

X.TUNE) of the process controller.

• Add the

F.CONTROL auxiliary function to the main menu using the

configuration menu (

ADDFUNCTION) and make settings.

• Make settings in the

BUS.COMM function.

• Configuration of the process values.

13.1. settings in BUS.COMM

Address 0

Enter a device address (value between 0 and 126)

BUS FAIL

Activate or deactivate approach of the safety
position

SafePos off

The actuator remains in the position which cor-
responds to the set-point value last transferred
(default setting).

SafePos on

If there is a fault in the bus communication, the
behavior of the actuator depends on the acti-
vation of the

SAFEPOS auxiliary function.

SAFEPOS activated:
The actuator moves to the safety position which is specified in the

SAFEPOS auxiliary function.

SAFEPOS deactivated:
The actuator moves to the safety end position which it would

assume if the electrical and pneumatic auxiliary energy failed.
See Chapter “15. Safety end positions”.