Output - configuration of the analog output, See chapter “12.3. output - configuration of, The analog output – Burkert Type 8750 User Manual

Page 34

Advertising
background image

34

Additional FMR functions

Typ 8750

CAL.USER - settings:

calibr. POS

calibration of the position actual value

POS. pMIN

Set the minimum position of the valve

POS. pMAX

Set the maximum position of the valve

CAL.FMR

calibration of the flow controller

CAL.PLIM

Measurement range of the pressure sensor

CAL.P1

Calibration of pressure sensor 1

CAL.P2

Calibration of pressure sensor 2

CAL.P1‘P2

P1-P2 comparison increase in accuracy

CAL.TLIM

Measurement range of the temperature
transmitter

CAL.TEMP

Calibrating the temperature transmitter

calibr. SP

calibrating the process set-point value

SP 4mA 0

Minimum value of the input signal

SP 20mA 0

Maximum value of the input signal

calibr. PV

calibrating the process actual value

for input signal 4 - 20 mA:

PV 4mA 0

Minimum value of the input signal

PV 20mA 0

Maximum value of the input signal

for input signal Pt 100:

0000

Temperature

copyFACT->USER reset to factory settings

Tab. 23: CAL.USER settings

12.3. OUTPUT - configuration of the

analog output

The analog output can send feedback regarding the current position
(POS) or the set-point value (CMD), the process actual value (PV),
the process set-point value (SP), the pressure at the input (P1), the
pressure at the output (P2) or the medium temperature (MTMP) to
the control center.

Add the auxiliary function

OUTPUT to the main menu using the

configuration menu (

ADDFUNCTION).

Create the settings for the flow controller under

OUT ANALOG.