Master code, English – Burkert Type 8750 User Manual

Page 17

Advertising
background image

17

Control and display elements

Typ 8750

description of the display

display

Simultaneous display of the nominal position
and the set-point position of the valve
actuator (0 – 100 %)

MENU

CMD/POS

POS MANU

0.0

sp

pV

0.0

m3/min
m3/min

Graphical display of SP and PV with time
axis

MENU

HOLD

SP / PV (t)

Graphical display of POS and CMD with
time axis

MENU

HOLD

CMD / POS (t)

Value overview
Pressure sensor P1 and P2

MENU P.LIN SP/PV MANU

0.0

p1 bar

p2 bar

0.0

Time, weekday and date

MENU

POS (t)

X.TUNE

INPUT

12:00

00

thu. 01 . 09 . 11

CLOCK

Automatic adjustment of the position
controller

MENU

CLOCK

P.TUNE RUN

X.tune

description of the display

display

Automatic optimization of the process con-
troller parameters

MENU

X.TUNE

P.LIN

RUN

p.tune

Automatic linearization of the process
characteristics

MENU

P.TUNE

CMD/POS

RUN

p.lin

Simultaneous display of the nominal position
and the set-point position of the valve
actuator
(0 – 100 %)

MENU P.LIN SP/PV MANU

0.0

cmd

pos

0.0

Tab. 6: Display in the AUTOMATIC operating state

8.5. master code

Operation of the device can be locked via a freely selectable user
code. In addition, there is a non-changeable master code with which
you can perform all operator control actions on the device. This
4-digit master code can be found on the last pages of this quickstart
guide in the Chapter “Master code”.
If required, cut out the code and keep it separate from this quickstart
guide.

english

Advertising