Examples of ml-drive applications, Examples of ml-drive applications -4, Code select set point tach – CONTREX ML-Drive User Manual

Page 12

Advertising
background image

1 - 4

EXAMPLES OF ML-DRIVE

APPLICATIONS

Figure 1-1 is an example of a Master mode of operation for a pump application. The
scaling format allows the operator to enter a setpoint in Engineering Units of gallons per
minute. The ML-Drive compares the sensor shaft feedback to the scaled setpoint and
calculates any speed error. When the ML-Drive finds speed error, the control algorithm
adjusts the drive output and reduces the error to zero.

Figure 1-1 ML-Drive Master Mode

ML-Drive

Motor

Sensor

Pump

Feedback Frequency

Drive

Output

Contrex

CODE

SELECT

SET

POINT

TACH

7

8

9

4

5

6

1

2

3

0

.

ENTER

CLEAR

Advertising