CONTREX ML-Drive User Manual

Page 44

Advertising
background image

3 - 10

Table 3-4 Default Master Scaling Control Parameters

CP

Parameter Name

Parameter Value

CP-34

Max RPM Feedback

2000

CP-31

PPR Feedback

60

CP-20

Master Engineering Units

2000

Table 3-5 Entering Master Scaling Control Parameters

CP

Parameter Name

Parameter Value

CP-34

Max RPM Feedback

CP-31

PPR Feedback

CP-20

Master Engineering Units

Enter the maximum desired RPMs,
measured at the sensor shaft.

Enter the number of gear teeth or
encoder lines on the sensor per one
revolution (pulses per revolution).

Enter the Master Engineering Units
value if the system were to operate at
the maximum desired RPMs entered in
CP-34.

Now that your scaling has been established, you can enter a value for Master
Setpoints 1 and 2. The value that you enter for a setpoint is the Engineering Units
(E.U.s) that you want to operate your system at.

The factory default Control Parameters for Master Setpoint 1 and 2 are set at “0”. To
modify these default parameters, refer to Table 3-6. You can toggle between the two
setpoints, if you have wired the Setpoint Select accordingly. Setpoint Select (located
at J4 pins 13, 14) determines which of the two setpoints is active (refer to

Setpoint

Select

on page 2-12). If you are uncertain how to enter a Control Parameter, review

the

Operations: Keypad

section, page 3-3.