CONTREX ML-Drive User Manual

Page 146

Advertising
background image

C - 10

MP-58 SERIAL COMMUNICATIONS ERROR

Serial Communications Error (MP-58) identifies errors in the last transmitted message that was
sent to the ML-Drive by the host computer. The mode that displays a number “1” indicates the
error. In the example below, “Invalid Parameter Code” is the error.

Structure Error (Parity,Framing,No ETX, No STX)

Invalid Parameter Code

Invalid Parameter Data or Out of Data Min-Max Range

Control Mask Error

Code

MP-59 FREQUENCY OVERFLOW COUNTER

The Frequency Overflow Counter (MP-59) is a counter that increments each time the frequency
input to the ML-Drive causes an overflow. To reset the counter to “0”, press the Clear key.

CP-61

DIRECT ENABLE

In the Direct mode of operation, the drive output from the ML-Drive that is connected to the
motor can be set directly. Direct mode is an open-loop mode of operation. Use Direct Enable
(CP-61) to either enable or disable the Direct mode.

Enter "1" to enable the Direct Mode.
Enter “0” to disable the Direct Mode.