CONTREX ML-Drive User Manual

Page 55

Advertising
background image

3 - 21

Table 3-12 Follower Mode Control Parameters Example B

CP

Parameter Name

Parameter Value

CP-33

Max RPM Lead

1800

CP-34

Max RPM Feedback

1800

CP-30

PPR Lead

60

CP-31

PPR Feedback

30

CP-21

Follower E.U.

50

CP-03

Follower Setpoint 1

50

CP-04

Follower Setpoint 2

70

The ML-Drive will adjust and monitor the speed of the motors to achieve the desired
gallons/minute. That completes the scaling and setpoint information for Example B.

After the Control Parameters for the Scaling and for the Follower setpoint have been
entered, you can enter the Control Parameters for the Acceleration/Deceleration of the
Follower mode. The Control Parameters for Acceleration/Deceleration are identical for
both the Master and the Follower modes of operations. Acceleration/Deceleration is
discussed in

Operation: Control Parameters, Acceleration/Deceleration,

page 3-26.