Jog -32 – CONTREX ML-Drive User Manual

Page 66

Advertising
background image

3 - 32

Jog

Jog increases the RPMs at the acceleration rate that you specified in Acceleration Time
(CP-16) until the Jog Setpoint (CP-05) is achieved. When Jog is terminated, there is no
Deceleration Time (CP-17); the drive comes to an immediate stop. The factory default
Control Parameter for Jog is found in Table 3-25. To modify this default parameter,
refer to Table 3-26. If you are uncertain how to enter a Control Parameter, review the

Operations: Keypad

section, page 3-3.

Table 3-25 Default Jog Control Parameters

CP

Parameter Name

Parameter Value

CP-05

Jog Setpoint

50

Table 3-26 Entering Jog Control Parameters

CP

Parameter Name

Parameter Value

CP-05

Jog Setpoint

Enter the RPM at which you want your
system to operate when it is in Jog.

For information on the Jog Logic Input, refer to

Logic Control: Logic Inputs, Jog,

page 3-36.