2 - 11

Figure 2-11 F–Stop

F–Stop

(J4 pins 10, 11)

F–Stop is a momentary input. When
it is open, the ML-Drive stops
immediately (zero RPM) and ignores
the specified deceleration rate. As a
momentary input, F-Stop is internally
latched and does not need to be
maintained by an operator device.

Master / Follower

(J4 pins 12, 14)

This input determines the ML–Drive's
mode of operation and resulting
scaling formula that the control
algorithm uses. The ML-Drive is in
Master mode when the circuit is
open, and Follower mode if the circuit
is shorted to the common.

Figure 2-12 Master / Follower

MASTER

12

14

J4

FOLLOWER

F-STOP

10

11

J4