PSA PIN388D/PIN388L Installer Manual User Manual

Page 19

Advertising
background image

18

PINKERTON Installer Manual

A

DDRESS

D

ESCRIPTIONS

U

SER

C

ODES


Name of
option

Address


Value allowed


Option Description

User 0
Master Code

000

4 digits

The Master code can turn the alarm ON and OFF and change
user codes and the temporary telephone number as well as
functions at address 252.

User 1

Installer Code

004

4 digits

The Installer code has access to all functions(except arming
and disarming) and addresses except address 252. The
Installer code can be disabled by the Master code at address
252.

User 2

008

4 digits

Has access to all functions except programming

User 3

012

4 digits

Has access to all functions except programming

User 4

016

4 digits

Has access to all functions except programming

User 5

020

4 digits

Has access to all functions except programming

User 6

024

4 digits

Has access to all functions except programming

User 7

028

4 digits

Has access to all functions except programming

User 8

032

4 digits

Can only turn the system ON and OFF

User 9

036

4 digits

Can only turn the system ON and OFF

User 10

040

4 digits

Can only turn the system ON and OFF

User 11

044

4 digits

Can only turn the system ON and OFF

User 12

048

4 digits

Can only turn the system ON and OFF

User 13

052

4 digits

Can only turn the system ON and OFF

User 14

056

4 digits

Can only turn the system ON and OFF

Usr 15

060

4 digits

Can only turn the system ON and OFF

- To erase a code, enter



in place of the first digit.

- See address 096, option 7 for information on the use of user codes 2 - 15 as Power Codes.


Master

Installer

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Turn ON/OFF Home mode and Away mode Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Keypad Panic Y

Y

Keypad Duress Y

Y

Keypad Test Y

Y

Isolate zones Y

Y

Y

Y

Y

Y

Y

Y

Review memory Y

Y

Y

Y

Y

Y

Y

Y

Program User codes Y

Y

Program Temporary telephone number Y

Y

Program system addresses

Y

Program address 252 Y
Program address 255

Y

Panel reset Y

Y

Remote access by telephone Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Remote access by PSA-Connect

Y

¹ If Powercodes are enabled, Codes 2-15 do not have access
to Panic, Duress, Test functions at the keypad.

Advertising