27


Name of
option

Address


Value allowed


Option Description

Factory
defaults

250


1,5,7,8
2,5,7,8
3,5,7,8
4,5,7,8

At this address, enter:
1,5,7,8 Local default - dialler disabled (local factory default)
2,5,7,8 Personal reporting to private phone or mobile phone
(dialler factory default)
3,5,7,8 Domestic monitored (without open/close reports)
4,5,7,8 Business monitored (all dialler options enabled)



Special
functions for
Master Code

252

Select 1, 2, 3

1 No

installer.

Setting this option will completely disable the installer
code. Note, this applies to PINKERTON V18 onwards. In
previous versions, this option only prevents the installer
code from programming the PINKERTON system.

2 No computer access.

Setting this option will prevent the system from
communicating with PSA Connect remote access
software.

3 No

telephone

arming.

Setting this option will prevent the system from being
turned ON or OFF using a remote telephone. The system
will still answer the telephone (if the option is set) and
annunciate it’s ON/OFF status.


Panel reset

254

When in
programming
mode,
enter 254.
Accessing the
address
performs the
panel reset.

This option is available to the Installer code and the Master
code. Panel reset is the same as “booting” your computer. No
data or programming is lost. Simply, the microprocessor is re-
started.
Panel reset is required after programming for some functions
to work correctly. For example, do a reset after programming
test reports to initialise the first test report. As a rule. It is good
practise to reset the panel when you have finished
programming the system.

HANDY HINT:

After a reset, if you dial into the system within 60
seconds, it will answer the telephone after 2 rings instead
of the programmed number of rings. This is a handy way
of quickly accessing the system with PSA Connect
software or by remote telephone.


Special
function for
Installer Code

255

Enter 9

This option is only available to the Installer code. Setting this
option to “9” will prevent the system from being defaulted in
any way including initialising of the Installer code with the “KY
power up” .

WARNING:
WHEN THIS OPTION IS SET THE INSTALLER CODE CAN
NEVER BE RECOVERED. IF YOU FORGET YOUR
INSTALLER CODE, THE SYSTEM MUST BE RETURNED
FOR SERVICE.

Advertising