24

PINKERTON Installer Manual


Name of
option

Address


Value allowed


Option Description

Panel
Options 2

098

Select 1 - 8

1 Exit beep
If this option is turned on, the keypad beeper will sound

continuously during exit delay. If any key is pressed during
exit delay, the beeper will stop sounding. If this option is
turned off, the system will not beep continuously during exit
delay but will give three beeps at the end of exit delay.


2 Entry beep
If this option is turned on, the keypad beeper will sound

continuously during entry delay. If any key is pressed
during entry delay, the beeper will stop sounding.


3 Exit squawk
If this option is turned on, the siren output will squawk

momentarily at the end of exit delay. The duration of the
squawk is set by address 110.


4 Entry squawk
If this option is turned on, the siren output will squawk

momentarily at the start of entry delay. The duration of the
squawk is set by address 110.


5 Home squawk
If this option is turned on, the siren output will squawk

momentarily every time a Home Beep Zone is triggered in
Home mode. The duration of the squawk is set by address
110.


6 ON/OFF squawk or flash
If this option is turned on, the siren output will squawk or

the strobe output will flash when the system is turned ON
and OFF using the KY keyswitch input.


7 Home instant
If this option is turned on, all Zones in Home mode will be

instant even if programmed for delay. This does not affect
delay timers in Away mode.


8 No Quick Arming if low battery
If this option is turned on, the panel will check the state of

the battery charging voltage prior to turning the system ON

with the quick arm sequence



and if the battery is low

will not allow the panel to be turn on. The system can
always be turned on with a code.