PINKERTON Installer Manual


Name of
option

Address


Value allowed


Option Description

General
options

240

Select 1, 4, 6, 7

1 Enable external inputs.

Enables the three additional inputs on the expansion pins
on the Pinkerton main board. These inputs are labelled
Panic, Duress and Test and are treated as normal Zone
inputs when enabled - resistors are required. Note that no
restoral reports are sent by these three inputs.

2 & 3 Zone Input Sensitivity

The response time of the Zone inputs can be increased to
allow the use of vibration sensors on one or more Zone
inputs. Turn lights 2 and 3 on or off to adjust for high,
medium or low sensitivity. Note that the setting will apply
to all Zone inputs.

Input sensitivity Light

2 Light

3

Normal (default) OFF

OFF

High

ON

OFF

Medium

OFF

ON

Low

ON

ON


4 Squawk

or

Flash.

Sets the option for either audible or visual indication of the
ON/OFF state of the system.

Light 4
Strobe flash On
Siren squawk Off

Address 098, option 6 must also be on for siren squawk
and strobe flash to work.

5 not

used

6 Zone 8 home key.

When selected, Zone 8 is used to turn the system ON in
home mode.

7 SIREN

TOGGLE

When selected, this option will cause any activation of
Zone 7 to toggle the siren ON and OFF. Note that if the
siren was triggered by an alarm condition, Zone 7 will not
toggle the siren OFF.

8 not

used

Attempts
before fail to
communicate

242

00 - 10
attempts

Sets the number of unsuccessful dialling attempts the system
will make before triggering Fail to Communicate. (Actions
triggered by Fail to Communicate are set at address 066).

Zone pulse
count

243

00 - 99 counts

Sets the number of Pulse Zones which may be triggered
before generating an alarm condition.

Zone pulse
time

244

00-165 seconds Sets the time during which the system will count triggers from

Pulse Count Zones.