A

DDRESS

D

ESCRIPTIONS

L

OCAL

&

D

IALLER

V

ERSIONS


Name of
option

Address


Value allowed


Option Description

Zone Option
Section 1
&
System
Inputs

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Open/Close

Fail to Comm

Duress Input

Panic Input

Test Input

Low Battery

AC Fail






070

072

074

076

078

080

082

084

064

066

086

088

090

092

094

Select 1 - 8

1 Handover

Zones selected for handover have entry delay as long as a
delayed Entry Delay Zone has been triggered first (see
next page). If a Handover Zone is triggered before an Entry
Delay Zone, the alarm will be instant. Note that delay will
be ignored if selected for 24 hour inputs. In home mode,
there will be no delay if the Home Instant option is set
(address 098, option 7).
If during entry delay an instant alarm occurs, this will be
actioned immediately without affecting the delayed inputs
operation.
If the system is turned ON in Home Mode and Home
Instant (address 098, option 7) has been enabled, then all
delayed inputs will be instant while the panel is in Home
Mode. All 24 hour inputs are treated as instant even if they
have been programmed for Handover or Entry Delay.
At the end of the entry delay, all delayed inputs that were
triggered will go into alarm unless the panel has been
turned OFF before the end of the entry delay.


2 Siren
Any active input can be programmed to trigger the siren.
When in Home Mode, there is a separate option for
enabling sirens for any Zone, see: Zone Options Section 2.

3 Dialler
Zones selected for dialler will trigger the dialler when

alarmed. If a Zone is triggered in Home Mode, it will only
trigger the dialler if the Home Report option is on. Selecting
Dialler for the Fail to Communicate input will be ignored.


4 Autoisolate
Zones selected for auto-Isolate will be isolated if still un-

sealed at the end of exit delay. Generally speaking the
Auto Isolate option is not programmed for 24 hour inputs


5 Strobe
Any active input can been programmed to trigger the

strobe. When in Home Mode, there is a separate option for
enabling strobe for any Zone, see: Zone Options Section 2.


6 Away
Zones selected for Away will be armed at the end of exit

delay when panel is turned on in Away mode.


7 Home
Zones selected for Home will be armed at the end of exit

delay when panel is turned on in Home mode.


8 24hr
Zones selected as 24hr will be permanently armed.

Note:

The system must be reset for this change to take

effect.