B

ASE STATION MONITORED REPORTING

H

IGH SPEED

The system sends Ademco high speed reports in extended format. This format is pre-set and
requires no further programming.

C

ONTACT

ID

Ademco Contact ID allows Zone descriptive information to be sent to the Central Station. There
are about 200 or so standard messages to choose from, each message has a 3 digit identifier. The
system allows you to choose a 3 digit message for every logical input. The messages start at
address 176. Each message must be 3 digits. For a complete list of all possible messages, contact
your Central Station.

Zone bypass uses the fixed message "570" which will be displayed at the central station as "Zone
Bypass".

User reporting codes are the same as for Ademco fast format and are listed below:

Code reported

Caused by

Code F

Code 15 on/off

Code E

Panel on reset or Code 14 on/off

Code D

Quick-arm sequence or Code 13 on/off

Code C

Key-switch or Code 12 on/off

Codes 0 to B

Code 0 to Code 11 on/off