PSA PIN388D/PIN388L Installer Manual User Manual

Page 24

Advertising
background image

PINKERTON Installer Manual

23


Name of
option

Address


Value allowed


Option Description

Panel
Options 1

096

Select 1 - 7

1 Display lights
If this option is turned off, the keypad will not display Zone

lights. On-Line, Low Batt, AC Fail and On will still display.


2 Quick Away

Allows the use of



to turn the panel on to Away

Mode.

3 Quick Home

Allows the use of



to turn the panel on to Home

Mode.

4 Code 15 once
Allows user code 15 to only turn the panel off once only. As

soon as the code is used, it is automatically erased. Handy
as a single use code to be handed out to temporary staff or
cleaners etc.


5 AC Fail delay
Normally AC Fail is immediately reported (if programmed to

do so) as soon as AC power is interrupted. When AC Fail
delay is selected, the panel does not report power failure
unless power is interrupted for longer than 30 minutes.
Note that in idle mode the keypad lights display the current
state of this input with no delay.


6 Quick review

Allows the use of



to review the panel memory

(previous alarms etc, see page 13).


7 Power Codes
Allows user codes 2 – 15 to turn the system ON and OFF

without the use of the



or



keys.


8 Not used


Advertising