System Send_Commands (cont.)

Command

Description

'AKEYP-<number
string>'

Open the Touch Panel keypad and initialize the number string
entry. The keypad string is set to null during power-up and is
stored until power-down.

<number string> = 0 - 9999

Example:

SEND_COMMAND TP,'AKEYP-1988'

Opens the Touch Panel keypad with 1988 in the display.

'AKEYR'

Close the Touch Panel keyboard or keypad opened with the
'AKEYB', 'AKEYP', or 'PKEYP' commands.

Example:

SEND_COMMAND TP,'AKEYR'

Closes the keyboard or keypad opened using the

'AKEYB'

,

'

AKEYP'

, or '

PKEYP'

commands.

'BEEP'

Output one beep. The Beep button in the Protected Setup
page must be set to 1 - 10 for this command.

Example:

SEND_COMMAND TP,'BEEP'

Beeps the panel if the Beep button is not set to 0.

'BRIT=<level>'

Adjust brightness of display. The brightness range is 1
(minimum) to 8 (maximum).

<level> = 1 - 8

Example:

SEND_COMMAND TP,'BRIT=8'

Sets to highest brightness level.

'CALIBRATE'

Start Touch Panel calibration.

Example:

SEND_COMMAND TP,'CALIBRATE'

Starts the calibration operation on the Touch Panel.