Using the axlink connector for data and power – AMX G3 User Manual

Page 23

Advertising
background image

Color Active-Matrix LCD Touch Panels

Installing Touch Panels

15

Using the AXlink connector for data and power

Connect the control system’s AXlink connector to the AXlink connector on the rear
of the Touch Panel for data and 12 VDC power as shown in Figure 14.

PWR (+)

AXM

AXP

GND (-)

AXlink connector

Control system

PWR (+)

AXM

AXP

GND (-)

Using the AXlink connector with an external 12 VDC power supply

Connect the control system’s AXlink connector to the AXlink connector on the rear
panel of the Touch Panel as shown in Figure 15.

PWR (+)

AXM

AXP

GND (-)

PWR (+)

AXM

AXP

GND (-)

AXlink connector

Control system

12 VDC power supply

PWR (+)

GND (-)

Use an external 12 VDC power supply when the distance between the control
system and Touch Panel exceeds the limits described in Figure 13. Make sure to
connect only the GND wire on the AXlink connector when using an external 12
VDC power supply. Do not connect the PWR wire to the AXlink connector’s PWR
(+) terminal.

Caution

If you are using power from

AXlink, disconnect the wiring

from the AXCESS Central

Controller before wiring the

Touch Panel.

Figure 14

AXlink wiring diagram

Figure 15

AXlink and external 12 VDC

power supply wiring diagram

Advertising