AMX G3 User Manual

Page 19

Advertising
background image

Color Active-Matrix LCD Touch Panels

Installing Touch Panels

11

.125 [3.2 MM] MAX

CUTOUT

TWO .170 [4.3 MM] DIA HOLES PROVIDED ON

2.94

1.70

1.70

.125

4.25

7.10

7.46

7.80

.35

.170

.52

3.22

(FRAME)

(FRAME)

[74.7 MM]

[8.9 MM]

[180.3 MM]

8.187

4.50

2.

Insert a flat head screwdriver into the release slot on the AXU-CV(/PB)’s or
AXU-CA(/PB)’s bezel and remove the engraved overlay.

3.

Lay the AXU-CV(/PB) or AXU-CA(/PB) facedown onto a soft cloth and
remove the four screws from the low-profile back box. Remove the back box
and discard.

4.

Place the BB-TP1 into the cutout and mark the threaded insert positions as
shown in Figure 9.

5.

Remove the BB-TP1 and drill four #6-32 insert holes. Then, place a threaded
insert into each hole.

6.

Disconnect the AXlink connector from the AMX Central Controller that
supplies power and data to the AXU-CV(/PB) or AXU-CA(/PB). Then,
disconnect the DB-9 connector from the external RS-232 device connected to
the AXU-CV(/PB) or AXU-CA(/PB).

7.

Thread the incoming AXlink and RS-232 wiring through the BB-TP1 knockout.

Figure 9

AXU-CV(/PB) or AXU-

CA(/PB), and BB-TP1 cutout