SURVEY OF TESTS TABLE (Cont.)

Kind of Test

Requirements

Review & Testing

Interval

• On all doors and openings of the spraying area where

the hazard of contact with parts under high voltage

exists the presence of the high voltage shall be

safeguarded in such a way that the high voltage is

disconnected when entrance is gained. The inter-

lock shall satisfy the performance level d of EN ISO

13849-1. Other openings of the spraying area through

which parts under high voltage could be contacted

shall be locked in such a way to be only opened by

keys or tools. When using systems of types C-L and

D-L an interlock of the high voltage with all doors

and openings shall be installed to prevent an electric

shock of persons.

• All conductive components of the equipment, like

floor, walls, ceilings, fences, conveyors, workpiec-

es, containers for coating material, reciprocators or

elements or elements of construction etc. within the

spraying area, except for parts under high voltage

for operational reasons, shall be connected to the

grounding system. Parts of the booth shall be earthed

in compliance with EN 12215:2004.

• If an appropriate grounding of the conductive parts

according to 5.7.1 cannot be achieved, the possible

discharge energy shall not exceed 0, 24mJ.

• The resistance to earth from the suspending point of

each workpiece shall not exceed 1 MΩ. The voltage

during measurement shall be 500 V or 1000 V. The

construction of hangers shall ensure that the work-

pieces remain earthed during the coating process.

Note: Since workpieces are often earthed by metallic hooks,

it is important to clean these hooks regularly or to design

them in such a way, that the built-up of insulating layers of

coating materials is prevented.

• If an appropriate grounding of the workpiece accord-

ing to 5.7.1 cannot be ensured, the dissipation of

electrical charges at the workpiece by other devices,

e.g. ionizers, is permitted. Such devices shall not ex-

ceed the permitted discharge energy of the spraying

systems, for which they are used. Moreover, these

devices shall be submitted to the same test for ad-

missible discharge energy as the spraying systems

they are used with. The dissipation device shall be

interlocked with the spraying system in such a way

to disconnect the high voltage and to stop coating

in case of failure of this dissipation device.

Effectivity of measures

for protection against

direct contact

Interlocks / protection

against entrance

Effectivity of grounding

measures

Weekly

Weekly

Aerobell 168 - Appendix

Ransburg

LN-9247-13

100