Shaping airs, Fluid flow rate control, Target distance – Ransburg Aerobell 168 Atex Approved 13350 User Manual

Page 41: Ransburg

Advertising
background image

FLUID FLOW RATE

CONTROL

Externally mounted fluid regulators or gear pumps

are typically used to control fluid flow.

The atomizer assembly is equipped with valves

which are pneumatically operated to direct the

flow of paint to either the feed tube or dump line

Fluid Flow Rate Check

In the test mode , the flow rate can be measured

by removing the bell cup from the atomizer, turning

the fluid flow on, and capturing the material in a

graduated beaker or measuring cup for a fixed

period of time (shaping air, high voltage, and

turbine air must be off).

TARGET DISTANCE

The distance from the Aerobell 168 atomizer to

target affects the spray application. For instance,

closer distances give a smaller spray pattern and

greater efficiency. Increasing the distance will give

a larger pattern and possibly reduce efficiency.

If the distance is too great, material may “wrap

back” on the Aerobell 168. The safe distance for

the Aerobell 168 is 204mm or 8”. All ground ob-

jects must be prevented from entering this area.

SHAPING AIRS

Shaping air is used to shape the spray pattern.

The lower the pressure, the wider the pattern, and

conversely, higher pressures result in narrower

patterns. Shaping air does not help atomize the

material, but does assist in the penetration of

atomized particles into cavity areas. Shaping

air should be kept at a minimum consistent with

coating requirements. Excessive shaping air will

cause some atomized particles to blow by the

target not allowing full “wrap,” or paint particles

to bounce back onto the atomizer.

Note: When Mono Flex shape air configuration

is used, one of the inputs on the atomizer body

will be required to be plugged. Either input can

be used for Mono Flex (SAI or SAO).

Dual Flex Shaping Air Configuration

Both inputs are required. Pattern adjustment:

Increasing the inner air will make the pattern

smaller. Increasing the outer air will make the

pattern larger.

W A R N I N G

!

†

Danger of shock and/or personal injury

can occur. Proper ground procedures must

be followed. Personnel must never work

around the turbine when the turbine is spin-

ning or when high voltage is turned on.

W A R N I N G

!

†

The safe distance of use for type AB168

Electrostatic Bell is

204mm from the bell

cup to earthed parts. The end user must

ensure this distance, as a minimum is main-

tained and that grounded objects are pre-

vented from contacting the applicator bell

cup when the applicator is energized or op-

erating.

Aerobell 168 - Operation