Step 18

Step 17

Step 16

DISASSEMBLY PROCEDURES

(For Robot/Machine Mount Kits)

Remove the Microvalve Seat.

When reassembling the Microvalve

Seat tighten to 15-20 In.- lbs.

(1.68– 2.24 N-m)

Using the 5mm Hex Key Wrench re-

move the five (5) SHCS and detach

the Top Valve Plate from the Valve

Manifold.

Top Valve Plate

Valve Manifold

Five (5) SHCS

Tighten to 10-15 In.-Lbs.

(1.23-1.68 N-m)