Step 18
Step 17
Step 16
DISASSEMBLY PROCEDURES
(For Robot/Machine Mount Kits)
Remove the Microvalve Seat.
When reassembling the Microvalve
Seat tighten to 15-20 In.- lbs.
(1.68– 2.24 N-m)
Using the 5mm Hex Key Wrench re-
move the five (5) SHCS and detach
the Top Valve Plate from the Valve
Manifold.
Top Valve Plate
Valve Manifold
Five (5) SHCS
Tighten to 10-15 In.-Lbs.
(1.23-1.68 N-m)