Wiring the emergency-stop switch

In many cases multiple controllers are used in a single system.
To provide an emergency-stop function for the entire system, the controller circuit is designed in such a way that
a single EMG switch is able to actuate an emergency stop in all connected controllers.

[Internal emergency-stop circuit]


















(Note) The current consumption of the internal relay is 10 mA or less.

(Reference)

Cutoff voltage

Cutoff current

EMG switch on teaching pendant

30 VDC

3 A

PORT switch

24 VDC

0.1 A

[Example of recommended circuit]




















(Note) To cut off the motor drive power supply in conformance with safety category 2, connect 24V to the EMG

terminal and a contactor or other contact device to the MPI/MPO terminals. (Refer to 4.2.3; rush current:
8 A.)