IAI America RCP2-CF User Manual

Page 96

Advertising
background image

76

Overview of operation on the PC software

Select an applicable position data in the main window, and then click the [Home] button.

For details, refer to the operation manual for the teaching pendant or PC software.

Issuing a command from the PLC

Perform signal processing appropriate for the selected PIO pattern by referring to 7.2.1, “Standard
Specification.”

Issue a command after confirming that the position complete signal (PEND) has
turned ON.

If home return cannot be performed, confirm that the *pause signal and servo ON signal are ON and that
the safety circuit is released, and also check if any error message is displayed.


(11) Set the target position, speed, acceleration/deceleration, positioning band and other data in the position

table. For details on how to set these data, refer to the operation manual for the teaching pendant/PC
software.


Now, automatic operation can be performed via PLC link.


Timing chart at startup
































Note: If parameter No. 25 (PIO pattern) is set to “0: [Conventional],” “2: [64-point positioning]”

or “5: [4 points],” the servo ON input and ready output are not provided.

Safety circuit condition

24-VDC power ON

ALM lamp

*Pause input

(STP)

Servo ON input

(SON)

RUN lamp

Ready output

(SRDY)

Position complete output

(PEND)

Home return completion output

(HEND)

Home return operation

Emergency stop is actuated or
motor drive power is cut off

Emergency stop is not actuated
or motor drive power is supplied

Initial parameter settings

Pause is cancelled

Creation of position table using the
teaching pendant or PC operation

Lit

Ho

me

p

o

s

ition

M

e

chani

cal

en

d

S

ta

rt

of

mo

ve

men

t