[Load and Offset]



٧

PTP Operation

In the case that the actuator is moved with a transfer load of 10kg or less and a speed of 50% or

less, set the load offset to 70mm or less as shown in the following graph. When the speed is at

50%, the load offset is 70mm no matter what the transported load weight is.

0

10

20

30

40

50

60

70

0

10

20

30

40

50

Transported Load [kg]

Load Offset

[m

m

]

Speed 50%

Speed 75%

Speed 100%

٧

CP Operation

In the case that the actuator is moved with a transfer load of 20kg or less and a speed of 50% or

less, set the load offset to 70mm or less as shown in the following graph. When the speed is at

50%, the load offset is 70mm no matter what the transported load weight is.

0

10

20

30

40

50

60

70

0

10

20

30

40

50

Transported Load [kg]

Load Offset

[m

m

]

Speed 50%

Speed 75%

Speed 100%