3. Wiring and Piping

41

Refer to the operation manuals for the controller and PC software for the procedures to connect

the I/O cable, controller power cable, PC connection cable, etc.

Warning:

x

Connect to the robot of the serial number specified on the robot designation

label provided on the front panel of the controller.

Robot designation label

Robot Serial

Number

x

Do not attempt to use a cable out of the dedicated cable for connection.Doing

so may cause not only error operation or malfunction, but also may cause a

critical accident such as fire or injury.

x

When the cable is connected or disconnected, make to turn off the power to the

controller.

Working with the power being kept on may cause the robot to have an error

operation, which may lead to a critical accident resulting in injury or death.

x

When the connector connection is not correct, it would be dangerous because

of a malfunction of the robot. Rigidly fix the connectors with the screws

equipped to them.

x

Connect the cables securely after confirming that they are free from damage or

bent connector pins.

x

A mistake in the connector connections may cause an error operation. Check

the connector name before plugging in.

Connect each cable by aligning the indication on the marking tube on the cable

with the indication on the controller panel.

x

When installing the PG connector (D-sub connector), ensure correct orientation

of the connector.

x

Since the brake power supply circuit is on the primary side (high voltage side)

for the horizontal articulated robot, prepare a dedicated 24V DC power source

for it. Do not attempt to use the power source for the secondary circuit such for

I/O power supply in common.

The brake power to be supplied to the controller should be 24V DC r10% with

the current wattage of 10W.

It is necessary to increase the capacity of the brake power source when a

brake-equipped actuator is connected to a controller. [Refer to the section of

Power Source Capacity and Heat Generation in the instruction manual of the