IAI America IX-NNN12040 User Manual

Page 75

Advertising
background image

4. Maintenance inspection

69

3) Adjust each axis to the initial posture. The posture differs depending on the movement

direction. Click on “Display the explanation of initial posture” to check the explanations.

Make to work on with the emergency stop activated when moving the axes with hand.

Click on the “OK” button after the work is finished.

[Initial posture]



Arm1, Arm 2

Remove all the interferences of the peripheral devices, and set the posture to either of the

left arm system or the right arm system. It is set to right arm system when the unit is shipped

out.

Arm 2 =
Negative direction of coordinate

Arm 1 =
Positive direction of coordinate

Arm 1 =
Negative direction of coordinate

Arm 2 =
Positive direction of coordinate

For the position, put it apart from the stopper position for 10deg or more.

Setting it too close to the stopper, Error No. B0D “Stopper Pressing Operation Start Position

Error” may occur at operation.



Vertical Axis

For the position, put it apart from the coordinate 0mm (upward end) for 10mm or more.

Setting it at 10mm or less, Error No. B0D “Stopper Pressing Operation Start Position Error”

may occur at operation.



Rotation axis

There is no specific indication for the position of rotation shaft. It can be set at any position.

Initial posture of left arm system

Arm 1 = Positive direction of coordinate

Arm 2 = Negative direction of coordinate

Initial posture of right arm system (At the delivery)

Arm 1 = Negative direction of coordinate

Arm 2 = Positive direction of coordinate

Advertising
This manual is related to the following products: