4. Maintenance inspection

51

Replacement procedure

1) Until finishing the battery replacement, keep the controller turned on and do not

disconnect the encoder cable. (It is to protect from losing the absolute data even in a

case of the battery voltage error while the controller is booted (while the control power is

ON).)

2) When replacing the batteries, make to set the condition to the emergency stop (driving

power is OFF) while the controller is booted (control power is ON), remove the cover on

the robot base part while paying attention to the safety of the surroundings, and have the

replacement work for the absolute data backup batteries. The absolute data backup

batteries are located in the place as shown in the figure below.

3) After the battery replacement work, have the software reset or turn of the power to the

robot controller once and reboot it to start up the robot controller again.

Storage Area Absolute Data Backup Batteries

For J1-Axis

For J2-Axis

For

Vertical Axis

For Rotation Axis

Absolute Data Backup Batteries

Model No.

Product Life

AB-3

3 years