3. Wiring and Piping

43

Connect the Resectable and plug as shown in the figure below.















٧

ALM Display

If 24V DC current is flown to pins 36 and 37 on the D-sub 37-pin connector on the base side,

ALM display lamp turns on.

For instance, connect it to the controller or I/O and detect the robot alarm, and it enables to

inform an occurrence of an alarm by ALM display lamp turned on.

Specifications

Rated Voltage

24V DC

Rated Current

12mA

Illumination Color

Red LED















(2) User Tubing

Connect an air tube that you have prepared to the quick joint.

Specifications

Normal Service Pressure

0.8MP

Dimensions (outer diameter • inner

diameter) and Number of Tubes

I

6mmuI4mm 4 pieces

Working Medium

Air

Plug

Resectable

Pin No.

36

37

24V DC

0V

Base side

D-Sub Connector Receptacle with 37-Pin

1

37

0V

24V DC

36

2