Chapter 2: Hardware Description

Summit User Manual

10

Teledyne

LeCroy

2.3 Summit T2-16 Front Panel Description

When powered on, the Summit T2-16 activates the user-accessible controls and LEDs
on the front and rear panels.

Warning! Do not open the enclosure. There are no operator serviceable parts inside.

Refer servicing to Teledyne LeCroy.

The controls and LEDs are:

Power Switch (black): 1 = On and 0 = Off.

LCD Menus: Allows you to set up the Summit T2-16 and view status. See “LCD
Menus” on page 11
.

Up Arrow (top blue button): Move up in the LCD menu.

Select (middle blue button): Select or change an option.

Down Arrow (bottom blue button): Move down in the LCD menu.

Record LED: Lights when the Summit T2-16 is recording.

Trigger LED: Lights when the Summit T2-16 triggers on an event.

Status LED: Displays Analyzer status: blue = good or red = error.

Manual Trigger (right blue button): Forces a trigger.

UPSTREAM [15:8] and UPSTREAM [7:0] connectors: Connection to the probe or
MidBus module for the capture of upstream direction of the link.

DOWNSTREAM [15:8] and DOWNSTREAM [7:0] connectors: Connection to the
probe or MidBus module for the capture of downstream direction of the link.

REF CLK IN (Reference Clock In): Provides an optional alternative connection
from an external reference clock source to the Summit T2-16 analyzer.

Note: In standard configuration, the Summit T2-16 analyzer uses the reference
clock from a probe cable.