Using the sma trigger in on an avalanche, Using the bnc trigger out on sastracer – Teledyne LeCroy SAS Suite User Manual User Manual

Page 176

Advertising
background image

Version 6.25

SASSuite User Manual

166

LeCroy Corporation

Using the

SMA Trigger

In on an

Avalanche

Step 1 Attach an appropriate Trigger Out connector on a general

purpose test instrument to the SMA EXT IN connector using the
provided SMA cable or an SMA-to-BNC cable, as appropriate.

Step 2 In the SASSuite software, under Recording Options

(Avalanche)..., select the General Tab and click the radio
button Event Trigger under Recording Type.

Step 3 Select the Triggering/Filtering Tab. Under the Global Rules

section (or in one of the Sequence sections), click on the <Click
here to add an event>
link

Step 4 Select SMA Input, adjust the parameters to match the signal

expected from the external device, and click OK.

Step 5 Click on the <Click here to add an action> link, select Trigger,

then click OK.

Step 6 Select Start from the Record menu.

Using the

BNC Trigger

Out on

SASTracer

Step 1 Attach the BNC Trigger Out connector to an appropriate BNC

Trigger In connector on a general purpose test instrument using
the provided BNC cable

Step 2 In the SASSuite software, under Recording Options (UPAS

10K)..., select the Recording Rules Tab

Step 3 Select the New Event button and specify the protocol level

event desired to initiate the external Trigger Out signal.

Advertising