Sastrainer generation commands, General commands, Sas trainer generation commands – Teledyne LeCroy SAS Suite User Manual User Manual

Page 238

Advertising
background image

Version 6.25

SASSuite User Manual

228

LeCroy Corporation

SASTrainer Generation Commands

General

Commands

IDLE (n)

Generator will insert n idle dwords into gen stream

CLEAR_CREDIT_AVAIL

This commands clears the credit established with the command
WF_CREDIT_AVAIL. (See WF_CREDIT_AVAIL in following section
on Wait Commands for explanation).

RD_POS

Generator will insert one idle dword into gen stream, which will bring
current RD to positive level

RD_NEG

Generator will insert one idle dword into gen stream, which will bring
current RD to negative level

RD_ERROR

Generator will insert one idle dword into gen stream, which will
intentionally break RD sequence creating RD error

CONNECT

Generator will go through connection sequence using current
GenFile settings (gen mode, speed e.t.c.) Generation will not
resume until connection is established

DISCONNECT

Generator will break existing connection to DUT

PAUSE

Generator will come to a break and the user will be able to resume
generation by pressing Resume button on Generation toolbar.
Generator shall transmit idle dwords while in the Pause.

OUTPUT_ON

Takes the Trainer out of Electric Idle state. If it is already out of
Electric Idle, this is a NOP.

OOB Commands

COMINIT

Generator will send COMINIT OOB signals using current COMINIT
settings.

COMRESET

Generator will send COMRESET OOB signals using current
COMRESET settings.

COMWAKE

Generator will send COMWAKE OOB signals using current
COMWAKE settings.

COMSAS

Generator will send COMSAS OOB signals using current COMSAS
settings.

SATA_ALIGN

Generator will go through SATA_ALIGN stage of SATA SpeedNeg
process using current SATA_ALIGN settings.

SATA_D10_2

Generator will go through SATA_D10_2 stage of SATA SpeedNeg
process using current SATA_D10_2 settings.

SPEED_NEG_RCDT

Generator will go through SPEED_NEG_RCDT stage of SAS
SpeedNeg process using current SPEED_NEG_RCDT settings.

Advertising