Triggering a

SASTracer

System

To configure the analyzer to trigger on an input signal from the breakout board, perform
the following steps:

Step 1 Select Setup > Recording Rules to open the Recording

Options dialog. The Recording Rules page will display.

Step 2 Click the New Events button to open the New Events menu.

Step 3 Select Breakout Board Data from the New Events menu. This

will cause a button to appear in the Available Events area. The
button will be labeled Breakout Board.

Step 4 Drag the new button to the Global State Cell or to the cell faintly

marked Drag an event here to add another state. The Global
State Cell
allows you to set conditions that are globally true (i.e.,
always enabled). The cell marked Drag an event here to add
another state
is used to create event sequences - i.e., chains
of events leading to a trigger or other action. For further
explanation, see “Assigning an Action” on page 91.

Step 5 Right-click on the Breakout Board button to open a pop-up

menu.

Step 6 Select Properties from the pop-up menu. The Properties dialog

opens.

Advertising