3 interface specifications, 1 serial interfaces (com1), 3 interface specifications -7 – Proface APL3000B - Node Box PC User Manual

Page 30: 1 serial interfaces (com1) -7, Interface specifications, 7 2.3 interface specifications, Switch

Advertising
background image

Chapter 2 Specifications

2-7

2.3

Interface Specifications

This section describes the specifications of each interface of the PS-A Series unit.

2.3.1

Serial Interfaces (COM1)

This interface is used to connect an RS-232C (serial) cable. A D-sub 9-pin plug connector is used.

Use #4-40 (UNC) fixing clamps to fix the joint of the interspace.

„ Switch

The RI/5V change switch, corresponding to serial interface, is placed on the board which you opened the fan

cover or the memory slot cover. Refer to the following for more details of how to remove the fan cover or the

memory slot cover.

• The PS-A unit’s serial port is not isolated. When the host (PLC) unit is also not

isolated, be sure to connect the #5 SG (Signal Ground) terminal to reduce the risk

of damaging the RS-232C circuit.

• Inside the PS-A unit, the SG (Signal Ground) and FG (Frame Ground) terminals

are connected.

• When connecting an external device to the PS-A using the SG terminal, be sure

to check that no short-circuit loop is created when you setup the system.

Pin

Arrangement

Pin No.

Signal

Name

Direction

Meaning

1

CD

Input

Carrier Detect

2

RD(RXD)

Input

Receive Data

3

SD(TXD)

Output

Send Data

4

ER(DTR)

Output

Data Terminal Ready

5

SG

-

Signal Ground

6

DR(DSR)

Input

Data Set Ready

7

RS(RTS)

Output

Request to Send

8

CS(CTS)

Input

Send Possible

9

CI(RI)/5V

Input

Called status display/+5V Output
(Switching available

*1

)

*1 By the switch on the board of the inside of the unit, it is available to change RI/5V.

Shell

FG

-

Frame Ground (Common with SG)

SEE

3.3.1 Main Memory Installation (page3-13)

• When you switch RI/5V, you must turn off the power supply for PS-A. Otherwise,

it will cause malfunction.

• Prior to the switching action, confirm the interface specification for the other side

of the connection. Otherwise, it will cause malfunction.

9