„ I/O Device Configuration

Point the cursor to the [I/O Device Configuration] on the [Advanced] screen and press the [Enter] Key, so that

the following screen will be displayed.

On board Serial Port 1

Specifies an enabled/disabled state for the COM1. Select from [Disabled] or [Enabled]. The factory default

setting is [Enabled]. In addition, the factory default setting for Base I/O Address is [3F8], and for Interrupt is

[IRQ 4].

On board Serial Port 2

Specifies an enabled/disabled state for the COM2. Select from [Disabled] or [Enabled]. The factory default

setting is [Enabled]. In addition, the factory default setting for Base I/O Address is [2F8], and for Interrupt is

[IRQ 3]. The COM2 is used in the system.