Creating a panel cut – Proface APL3000B - Node Box PC User Manual

Page 40

Advertising
background image

Chapter 3 Hardware Installation

3-3

„ Creating a Panel Cut

Create the correct sized opening required to install the PS-A, using the installation dimensions given.

The installation gasket and the installation fasteners are required when installing the PS-A.

SEE

2.4.3 Panel Cut Dimensions (page2-13)

Check that the installation panel or cabinet’s surface is flat, in good condition and has no jagged

edges. Also, if desired, metal reinforcing strips can be attached to the inside of the panel, near

the Panel Cut, to increase the panel’s strength.

• Panel thickness should be from 1.6mm [0.06 in.] to 10.0mm [0.39 in.]. Decide the

panel’s thickness based on the level of panel strength required.

• For easier maintenance, operation, and improved ventilation, be sure to install

the PS-A at least 50 mm [1.97 in.] away from adjacent structures and other equip-

ment.

Panel

Panel Cut

Area

1.6mm [0.06 in.] to 10.0mm [0.39 in.]

Unit: mm [in.]

50

[1.97]

50

[1.97]

50

[1.97]

50

[1.97]

50

[1.97]

50

[1.97]

50

[1.97]

Advertising