4.INSTALLATION

I

M 1E8B0-01E

4-10

Table 4.3.1

Maximum Tightening Torque Values for Metal Piping N·m {kgf·cm}
[in-lbf]

Flange
Rating

Size
mm(inch)

15(0.5)

25(1)

40(1.5)

JIS

ANSI

DIN

10K

20K

150

300

PN 10/16

14{143}[124]

30{306}[265]

44{449}[389]

14{143}[124]

30{306}[265]

44{449}[389]

14{143}[124]

22{224}[195]

33{337}[292]

14{143}[124]

30{306}[265]

51{520}[451]

14{143}[124]

25{255}[221]

50{510}[442]

* Please use compressed non-asbestos fiber gasket, PTFE gasket or the gasket which has equal elasticity.

Table 4.3.2

Maximum Tightening Torque Values for PVC Piping N·m {kgf·cm}
[in-lbf]

Flange
Rating

Size
mm(inch)

15(0.5)

25(1)

40(1.5)

JIS

ANSI

DIN

10K

20K

150

300

PN 10/16

1.3{13}[12]

3.5{36}[31]

5.7{58}[50}

1.3{13}[12]

2.8{29}[25]

4.6{47}[41]

1.3{13}[12]

2.7{28}[24]

5.7{58}[50}

* Please select optional code /FRG and use rubber gasket or others which has equal elasticity.