6-7

6. FUNCTION AND DATA SETTINGS

Display

Description

Select the volume unit for pulse weight using parameter number "F1".

Code

Volume Unit

00

01

02

03

04

05

06

Volume unit used in 10

-9

×

flow rate span

Volume unit used in 10

-6

×

flow rate span

Volume unit used in 10

-3

×

flow rate span

Volume unit used in 1

×

flow rate span

Volume unit used in 10

3

×

flow rate span

Volume unit used in 10

6

×

flow rate span

Number of pulses output per second at 100% of output

Code

Pulse Width

00

01

02

03

04

05

06

Example : When pulses are to be output per liter in a span of

m

3

/h, select "02" since L(liter) = 10

-3

×

m

3

Set the low cut range percentage in parameter "F3".
Range of setting : 0 to 100% (of span)

Set pulse weight "10 (L)" in parameter number "E2".

Select the pulse width in parameter number "F4".

Select instantaneous flow rate data or damped flow rate data for the pulse
output calculation. (The damped value is the value set in "B2".)

Set parameter "N2" to "01" when the pulse output transistor is to be off active.

Since parameter number "F2" is a 5-digit data item, scrolling is
necessary to display all the data. Mind the decimal point when
setting are made. (The decimal point can be moved if required.)

Default: 01
(Damped flow rate value)

Default: 00(ON ACTIVE)

Default: 3%

Default: 50%DUTY

50%DUTY

(Max. 1000P/s

min. 0.0001P/s)

0.5ms

(Max. 1000P/s

min. 0.0001P/s)

1ms

(Max. 500P/s

min. 0.0001P/s)

20ms

(Max. 25P/s

min. 0.0001P/s)

33ms

(Max. 15P/s

min. 0.0001P/s)

50ms

(Max. 10P/s

min. 0.0001P/s)

100ms

(Max. 5P/s

min. 0.0001P/s)

Normally, these are all required settings. The following settings are made depending on the applications

that are used.

*The "n" item can be opend by entering "55" in paramter number "L2".