Caution, Measurable flow range, Fluid temperature and pressure – Yokogawa ADMAG CA User Manual

Page 81

Advertising
background image

IM 1E8B0-01E

10-5

10. OUTLINE

• Measurable Flow Range:

Min. Range

@0.5m/s

Max. Range

@10m/s

15

25

40

50

80

100

150

200

0 to 0.3181

0 to 0.8836

0 to 2.2620

0 to 3.535

0 to 9.048

0 to 14.138

0 to 31.81

0 to 56.55

Size

0 to 6.361

0 to 17.671

0 to 45.23

0 to 70.68

0 to 180.95

0 to 282.74

0 to 636.1

0 to 1,130.9

SI Units (Size : mm, Flowrate : m

3

/h)

Min. Range

@1.6ft/s

Max. Range

@33ft/s

0.5

1

1.5

2

3

4

6

8

0 to 1.0040

0 to 4.016

0 to 9.036

0 to 16.063

0 to 36.15

0 to 64.26

0 to 144.57

0 to 257.01

Size

0 to 20.078

0 to 80.31

0 to 180.70

0 to 321.2

0 to 722.8

0 to 1,285.0

0 to 2,891.3

0 to 5,140

English Units (Size : inch, Flowrate : GPM)

Fluid Temperature and Pressure

MPa{kgf/cm

2

}(psi)

4{40}(580)

2{20}(290)

1{10}(145)

–0.1{–1}(–14.5)

Pressure

–10

(14)

0

(32)

120(248) Temperature

°

C(

°

F)

Diameter 15 (0.5") to 50mm (2")
Diameter 80 (3") to 200mm (8")

This limits show maximum allowable fluid pressure for Flow Tube itself.
Further fluid pressure should also be limitted according to flange rating.

Reasonable Figures for Thermal Shock for Ceramics

1. Size 15, 25mm (0.5, 1 in)

120(248)

100(212)

60(140)

T

°

C(

°

F)

Increase

Decrease

1(3)

5(15)

10(30)

Flow Velocity m/s(ft)

CAUTION