4.3.1.2. Mode "MAN x1, x2, x5"

4.

 Press the

START/STOP key once. The instrument carries out the

test injecting a current in phase with positive half wave of the
voltage indicated on

display by 0°.

 Press the

START/STOP key twice. The instrument carries out the

test injecting a current in phase with negative half wave of the
voltage indicated on

display by 180°.

NOTE: ”Man 5 I

n

” and “AUTO” test modes aren’t available for RCD type A

500mA.


 When the RCD trips if the tripping time

is within the limits reported in table, the
instrument emits a

double sound

signal indicating the positive
outcome
of the test and displays the
screen alongside.

RCD

~



40

ms

OK

N

30

m

A

1

V

x1

MAN

t

0° U

L

=

50

V


SAVING:

The test can be stored pressing the

SAVE key twice

(according to § 5.1).


RCD tripping time

OK: indicates that the RCD passed the test.

It indicates if the test was carried out with current
phase 0° or 180° with respect to the voltage.

Limit set for the
contact voltage.

Value of contact
voltage

U

t

detected referred
to the rated value
of the RCD
current set.

or RCD

SAVE

START

STOP