Example: typical syslog messages – Agilent Technologies E5810A User Manual

Page 123

Advertising
background image

Chapter 4

123

Troubleshooting Information

Checking PC Client Connections

Example: Typical

syslog Messages

This table shows typical syslog messages and provides a description of
each message, where the value in ( ), such as (0:00:00:18), is the time since
power-on expressed in Day (DD):Hour (HH):Minutes (MM):Seconds (SS).

ERROR: Firmware Update:
FTP server not found

Could not find FTP server specified.

ERROR: Firmware Update:
Invalid User Login or Password

Login or Password is invalid for the FTP server.

ERROR: Firmware Update:
Data not received from FTP
Server

Could not receive data from the FTP Server. May be trying to
access FTP server through a firewall.

ERROR: Firmware Update:
Invalid file or directory

Could not find file. Filename or directory is wrong.

ERROR: Firmware Update:
Internal error

Out of system resources. Reboot the E5810 and try again.

Message

Description

Message

Description

(0:00:00:00)

Selftest passed

Power-on self-test results

(0:00:00:00)

GPIB: Initialized, symbolic name = gpib0

GPIB and RS-232 initialized

(0:00:00:00)

RS232: Initialized, symbolic name = COM1

(0:00:00:18)

client: 156.140.104.184, id: 1 opened

Typical open/close messages (logged
each time a client opens or closes a
connection)

(0:00:00:18)

client: 156.140.104.184, id: 1 closed

(0:00:00:18)

client: 156.140.104.184, id: 1 opened

(0:00:00:19)

client: 156.140.104.184, id: 2 opened

(0:00:00:19)

client: 156.140.104.184, id: 3 opened

(0:00:39:21)

Max connections exceeded, client refused

Indicates the server had the maximum
number of connections when another
connection was requested, so the request
was refused.