Filters

This unit is not equipped with a filter or rack. A field provided

filter is required for the unit to operate properly. Table 3 lists

recommended filter sizes.

A filter must be in place whenever the unit is operating.

CAUTION

Solvent cements for plastic pipe are flammable liquids

and should be kept away from all sources of ignition.

Do not use excessive amounts of solvent cement when

making joints. Good ventilation should be maintained

to reduce fire hazard and to minimize breathing of

solvent vapors. Avoid contact of cement with skin and

eyes.

Duct System

Use industry-approved standards to size and install the

supply and return air duct system. This will result in a quiet

and low-static system that has uniform air distribution.

NOTE: This furnace is not certified for operation in heating

mode (indoor blower operating at selected heating speed)

with an external static pressure which exceeds 0.5 inches

w.c. Operation at these conditions may result in improper

limit operation.

Supply Air Plenum

If the fumace is installed without a cooling coil, a removable

access panel should be installed in the supply air duct. The

access panel should be large enough to permit inspection

(by reflected light) of the heat exchanger for leaks after the

furnace is installed. The furnace access panel must always

be in place when the furnace is operating and it must not

allow leaks into the supply air duct system.

Return Air Plenum

NOTE: Return air must not be drawn from a room where

this furnace, or any other gas-fueled appliance (i.e.,

water heater), or carbon monoxide-producing device

(i.e., wood fireplace) is installed.

When return air is drawn from a room, a negative pressure

is created in the room. If a gas appliance is operating in a

room with negative pressure, the flue products can be pulled

back down the vent pipe and into the room. This reverse

flow of the flue gas may result in incomplete combustion

and the formation of carbon monoxide gas. This toxic gas

might then be distributed throughout the house by the furnace

duct system.

Use fiberglass sealing strips, caulking, or equivalent sealing

method between the plenum and the furnace cabinet to

ensure a tight seal. If a filter is installed, size the return air

duct to fit the filter frame.

Pipe & Fittings Specifications

All pipe, fittings, primer and solvent cement must conform

with American National Standard Institute and the American

Society for Testing and Materials (ANSI/ASTM) standards.

The solvent shall be free flowing and contain no lumps,

undissolved particles or any foreign matter that adversely

affects the joint strength or chemical resistance of the

cement. The cement shall show no gelation, stratification,

or separation that cannot be removed by stirring. Refer to

Table 4 below for approved piping and fitting materials.

TABLE 4

PIPING AND FITTINGS SPECIFICATIONS

Schedule 40 PVC (Pipe)

D1785

Schedule 40 PVC (Cellular Core Pipe)

F891

Schedule 40 PVC (Fittings)

D2466

Schedule 40 CPVC (Pipe)

F441

Schedule 40 CPVC (Fittings)

F438

SDR−21 PVC or SDR−26 PVC (Pipe)

D2241

SDR−21 CPVC or SDR−26 CPVC (Pipe)

F442

Schedule 40 ABS Cellular Core DWV (Pipe)

F628

Schedule 40 ABS (Pipe)

D1527

Schedule 40 ABS (Fittings)

D2468

ABS−DWV (Drain Waste & Vent)
(Pipe & Fittings)

D2661

PVC−DWV (Drain Waste & Vent)
Pipe & Fittings)

D2665

PRIMER & SOLVENT CEMENT

ASTM

SPECIFICATION

PVC & CPVC Primer

F656

PVC Solvent Cement

D2564

CPVC Solvent Cement

F493

ABS Solvent Cement

D2235

PVC/CPVC/ABS All Purpose Cement For
Fittings & Pipe of the same material

D2564, D2235, F493

ABS to PVC or CPVC Transition Solvent
Cement

D3138

CANADA PIPE & FITTING & SOLVENT

CEMENT

MARKING

PVC & CPVC Pipe and Fittings

ULCS636

PVC & CPVC Solvent Cement

ABS to PVC or CPVC Transition Cement

TABLE 3

Furnace

Cabinet Width

Filter Size

16 x 25 x 1 (1)

17−1/2"

21"