FIGURE 28

FIELD SUPPLIED WALL TERMINATION

See venting Table 7 for maximum venting lengths with this
arrangement.

* Use wall support every 24" (610 mm). Use two wall supports if

extension is greater than 24" (610 mm) but less than 48" (1219 mm).

NOTE − One wall support must be 6" (152 mm) from top of each pipe

(intake and exhaust)

2" (51mm)

Vent Pipe

3" (76mm)

Vent Pipe

A −Minimum clearance

above grade or average

snow accumulation

B −Maximum horizontal

separation between

intake and exhaust

C −Minimum from

end of exhaust to

inlet of intake

D−Maximum exhaust

pipe length

E −Maximum wall support

distance from top of each

pipe (intake/exhaust)

12" (508MM)

12" (508MM)

6" (152MM)

6" (152MM)

8" (203MM)

8" (203MM)

12" (305MM)

20" (508MM)

6" (152MM)

6" (152MM)

NOTE − FIELD PROVIDED

REDUCER MAY BE

REQUIRED TO ADAPT

LARGER VENT PIPE SIZE

TO TERMINATION

D

B

C

SIZE TERMINATION

PER TABLE 8

1/2" (13mm) ARMAFLEX

INSULATION IN UN-

CONDITIONED SPACE

STRAIGHT

APPPLICATION

B

C

A

D

* WALL

SUPPORT

1/2" (13mm) ARMAFLEX INSULATION

IN UNCONDITIONED SPACE (IF REQUIRED)

E

EXTENDED

APPLICATION

A

(IF REQUIRED)

FIGURE 29

FIELD SUPPLIED WALL TERMINATION

See venting Table 7 for maximum venting lengths with this
arrangement.
* Use wall support every 24" (610 mm). Use two wall supports if

extension is greater than 24" (610 mm) but less than 48" (1219 mm).

NOTE − One wall support must be 6" (152 mm) from top of each pipe

(intake and exhaust)

2" (51mm)

Vent Pipe

3" (76mm)

Vent Pipe

12" (508MM)

12" (508MM)

6" (152MM)

6" (152MM)

6" (152MM)

12" (305MM)

20" (508MM)

6" (152MM)

6" (152MM)

6" (152MM)

A −Minimum clearance

above grade or average

snow accumulation

B −Maximum horizontal

separation between

intake and exhaust

C −Minimum from

end of exhaust to

inlet of intake

D−Maximum exhaust

pipe length

E −Maximum wall support

distance from top of each

pipe (intake/exhaust)

NOTE − FIELD PROVIDED

REDUCER MAY BE

REQUIRED TO ADAPT

LARGER VENT PIPE SIZE

TO TERMINATION

D

B

C

SIZE TERMINATION

PER TABLE 8

1/2" (13mm) ARMAFLEX

INSULATION IN UN-

CONDITIONED SPACE

STRAIGHT

APPPLICATION

B

C

D

* WALL

SUPPORT

1/2" (13mm) ARMAFLEX INSULATION

IN UNCONDITIONED SPACE (IF REQUIRED)

E

EXTENDED

APPLICATION

A

A

(IF REQUIRED)