INSTALLATION – Setting Equipment

Shipping Bolt Removal

NOTE: Units with a 1/2 hp blower motors are equipped with

three flexible legs and one rigid leg. The rigid leg is equipped

with a shipping bolt and a flat white plastic washer (rather

than the rubber mounting grommet used with a flexible

mounting leg). See Figure 8. The bolt and washer must

be removed before the furnace is placed into operation.

After the bolt and washer have been removed, the rigid leg

will not touch the blower housing.

WARNING

Blower access panel must be securely in place when

blower and burners are operating. Gas fumes, which

could contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

WARNING

Do not install the furnace on its front, back or in the

horizontal position. See Figure 10. Do no connect the

return air ducts to the back of the furnace. Doing so will

adversely affect the operation of the safety control

devices, which could result in personal injury or death.

Select a location that allows for the required clearances that

are listed on the unit nameplate. Also consider gas supply

connections, electrical supply, vent connection, condensate

trap and drain connections, and installation and service

clearances [24 inches (610 mm) at unit front]. The unit must

be level from side to side. Tilt the unit slightly (maximum

1/2 in. from level) from back to front to aid in the draining of

the heat exchanger. See Figure 9.

NOTE: These units may be equipped with a shipping pad

under the blower housing. Remove the shipping pad prior

to operation.

Allow for clearances to combustible materials as indicated

on the unit nameplate. Minimum clearances for closet or

alcove installations are shown in Figure 11.

Figure 10

FIGURE 8

RIGID LEG

(remove shipping bolt and washer)

UNITS WITH 1/2 HP BLOWER MOTOR

FIGURE 9

SETTING EQUIPMENT

FRONT VIEW

SIDE VIEW

AIR FLOW

AIR FLOW

1/2"

max.

AIR FLOW

SIDE VIEW

Unit must be level side−to−side. Unit may be positioned
from level to 1/2" toward the front to aid in draining.