Requirements for commonwealth of massachusetts – Allied Air Enterprises A95DF User Manual

Page 48

Advertising
background image

506725-01

Page 48 of 48

Issue 1109

REQUIREMENTS for COMMONWEALTH of MASSACHUSETTS

Modifications to NFPA-54, Chapter 10

Revise NFPA-54 section 10.8.3 to add the following

requirements:

For all side wall, horizontally vented, gas fueled equipment

installed in every dwelling, building or structure used in whole

or in part for residential purposes, including those owned or

operated by the Commonwealth and where the side wall

exhaust vent termination is less than seven (7) feet above

the finished grade in the area of the venting, including but

not limited to decks and porches, the following requirements

shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE

DETECTORS. At the time of installation of the side wall,

horizontally vented, gas-fueled equipment, the installing

plumber or gas fitter shall observe that a hard wired

carbon monoxide detector with an alarm and battery

backup is installed on the floor level where the gas

equipment is to be installed. In addition, the installing

plumber or gas fitter shall observe that a battery operated

or hard wired carbon monoxide detector with an alarm

is installed on each additional level of the dwelling,

building or structure served by the side wall, horizontally

vented, gas fueled equipment. It shall be the

responsibility of the property owner to secure the

services of qualified licensed professionals for the

installation of hard wired carbon monoxide detectors.

a. In the event that the side wall, horizontally vented,

gas fueled equipment is installed in a crawl space

or an attic, the hard wired carbon monoxide detector

with alarm and battery backup may be installed on

the next adjacent floor level.

b. In the event that the requirements of this subdivision

cannot be met at the time of completion of

installation, the owner shall have a period of thirty

(30) days to comply with the above requirements;

provided, however, that during said thirty (30) day

period, a battery operated carbon monoxide

detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS.

Each carbon monoxide detector as required in

accordance with the above provisions shall comply with

NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3. SIGNAGE. A metal or plastic identification plate shall

be permanently mounted to the exterior of the building

at a minimum height of eight (8) feet above grade directly

in line with the exhaust vent terminal for the horizontally

vented, gas fueled heating appliance or equipment. The

sign shall read, in print size no less than one half (1/2)

inch in size, “GAS VENT DIRECTLY BELOW. KEEP

CLEAR OF ALL OBSTRUCTIONS.”

4. INSPECTION. The state or local gas inspector of the

side wall, horizontally vented, gas-fueled equipment shall

not approve the installation unless, upon inspection, the

inspector observes carbon monoxide detectors and

signage installed in accordance with the provisions of

248 CMR 5.08(2)(a) 1 through 4.

EXEMPTIONS: The following equipment is exempt from

24 CMR 5.08(2)(a) 1 through 4:

1. The equipment listed in Chapter 10 entitled “Equipment

Not Required to Be Vented” in the most current edition

of NFPA 54 as adopted by the Board; and

2. Product Approved side wall, horizontally vented, gas

fueled equipment installed in a room or structure

separate from the dwelling, building or structure used in

whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS -

GAS EQUIPMENT VENTING SYSTEM PROVIDED.

When the manufacturer of Product Approved side wall,

horizontally vented, gas fueled equipment provides a venting

system design or venting system components with the

equipment, the instructions provided by the manufacturer

for installation of the equipment and the venting system shall

include:

1. Detailed instructions for the installation of the venting

system design or the venting system components: and

2. A complete parts list for the venting system design or

venting system.

MANUFACTURER REQUIREMENTS -

GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.

When the manufacturer of Product Approved sidewall,

horizontally vented, gas fueled equipment does not provide

the parts for venting the flue gases, but identifies “special

venting systems,” the following requirements shall be

satisfied by the manufacturer:

1. The referenced “special venting system” instructions

shall be included with the appliance or equipment

installation instructions; and

2. The “special venting systems” shall be Product

Approved by the Board, and the instructions for that

system shall include a parts list and detailed installation

instructions.

A copy of all installation instructions for all Product

Approved side wall, horizontally vented, gas fueled

equipment, all venting instructions, all parts lists for

venting instructions, and/or all venting design

instructions shall remain with the appliance or

equipment at the completion of the installation.